{"id":3412,"date":"2018-03-25T20:56:14","date_gmt":"2018-03-25T19:56:14","guid":{"rendered":"http:\/\/www.datinstruments.com\/en\/?p=3412"},"modified":"2018-03-26T10:03:12","modified_gmt":"2018-03-26T09:03:12","slug":"gin-grouting-intensity-number-online-calculator","status":"publish","type":"post","link":"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/","title":{"rendered":"GIN, grouting intensity number, online calculator"},"content":{"rendered":"<p style=\"text-align: justify;\">This is a GIN, grouting intensity number, online calculator. It is useful to evaluate if a grout injection is within GIN specifications. To use this calculator:<br \/>\n&#8211; set the length of the treatment (expressed in meters) and the grout pressure unit of measurement;<br \/>\n&#8211; set maximum injection parameters (grout pressure, grout volume in liters per meter, GIN in bar * liters \/ meters);<br \/>\n&#8211; write current injection values (current grout pressure, current grout volume in liters);<br \/>\n&#8211; the output helps you to continue or stop the grout injection.<\/p>\n<p><style>@media (max-width:480px){#cp_calculatedfieldsf_pform_1{min-height:729px;}}@media (max-width:768px){#cp_calculatedfieldsf_pform_1{min-height:727px;}}@media (max-width:1024px){#cp_calculatedfieldsf_pform_1{min-height:726px;}}@media (min-width:1024px){#cp_calculatedfieldsf_pform_1{min-height:788px;}}<\/style><form name=\"cp_calculatedfieldsf_pform_1\" id=\"cp_calculatedfieldsf_pform_1\" action=\"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/\" method=\"post\" enctype=\"multipart\/form-data\" onsubmit=\"return fbuilderjQuery.fbuilder.doValidate(this);\" class=\"cff-form \"  dir=\"ltr\" data-nonce=\"29b1f5cdc7\">\n<input type=\"hidden\" name=\"cp_calculatedfieldsf_pform_psequence\" value=\"_1\" \/>\n<input type=\"hidden\" name=\"cp_calculatedfieldsf_id\" value=\"9\" \/>\n<input type=\"hidden\" name=\"cp_ref_page\" value=\"https:\/\/www.datinstruments.com\/en\" \/>\n<pre style=\"display:none !important;\"><script type=\"text\/javascript\">form_structure_1=[[{\"form_identifier\":\"\",\"name\":\"fieldname15\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":0,\"ftype\":\"fSectionBreak\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"GIN injection set up\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname14\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":1,\"ftype\":\"fradio\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Set pressure unit of measurement\",\"layout\":\"side_by_side\",\"required\":false,\"exclude\":false,\"readonly\":false,\"toSubmit\":\"value\",\"choiceSelected\":\"BAR - 1\",\"showDep\":false,\"untickAccepted\":true,\"onoff\":0,\"choices\":[\"BAR\",\"MPa\",\"PSI\"],\"choicesVal\":[\"1\",\"10\",\"0.06894757\"],\"choicesDep\":[[],[],[]],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname24\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":2,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Set length of the borehole injection interval [m]\",\"predefined\":\"1\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname21\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":3,\"ftype\":\"fSectionBreak\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Grout injection parameters\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname2\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":4,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Maximum grout Pressure value\",\"predefined\":\"5\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname27\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":5,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Maximum grout Volume to inject [l\\\/m]\",\"predefined\":\"500\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname18\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":6,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"GIN, grouting intensity number [bar*l\\\/m]\",\"predefined\":\"750\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname12\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":7,\"ftype\":\"fSectionBreak\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Current injection values\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname29\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":8,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Grout Pressure\",\"predefined\":\"5\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname30\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":9,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Grout Volume [l]\",\"predefined\":\"500\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname28\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":10,\"ftype\":\"fSectionBreak\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Test results\",\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname31\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":11,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"(function(){\\nif (fieldname29 \\u003E fieldname2) return \\u0022Stop injection or reduce pressure - Overpressure\\u0022;\\nif (fieldname30 \\u003E= fieldname27 * fieldname24) return \\u0022Stop injection - Grout quantity complete\\u0022;\\nif (fieldname29 * fieldname14 * fieldname30 \\\/ fieldname24 \\u003E= fieldname18) return \\u0022Stop injection or reduce pressure - GIN\\u0022;\\nreturn \\u0022Continue injection\\u0022;\\n})();\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":false,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"}],{\"0\":{\"title\":\"\",\"description\":\"\",\"formlayout\":\"top_aligned\",\"formtemplate\":\"\",\"evalequations\":1,\"autocomplete\":1,\"persistence\":0,\"customstyles\":\"\",\"titletag\":\"H2\",\"textalign\":\"default\",\"headertextcolor\":\"\",\"evalequations_delay\":0,\"evalequationsevent\":2,\"direction\":\"ltr\",\"loading_animation\":0,\"animate_form\":0,\"animation_effect\":\"fade\"},\"formid\":\"cp_calculatedfieldsf_pform_1\"}];<\/script><\/pre>\n<div id=\"fbuilder\">\n\t\t<div id=\"fbuilder_1\">\n\t\t<div id=\"formheader_1\"><\/div>\n\t\t<div id=\"fieldlist_1\"><\/div>\n\t\t<div class=\"clearer\"><\/div>\n\t<\/div>\n<\/div>\n\t<div class=\"clearer\"><\/div>\n\t<input type=\"hidden\" id=\"_cpcff_public_nonce\" name=\"_cpcff_public_nonce\" value=\"d3bdd10857\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/en\/wp-json\/wp\/v2\/posts\/3412\" \/><\/form>\n\t<br \/>\n<a href=\"http:\/\/www.datinstruments.com\/en\/grouting-gin\/\">Automatic GIN injection recorder and controller<\/a><\/p>\n<p>Reference:Giovanni Lombardi, Grouting design and control using the GIN Principle, 1993<\/p>\n<hr \/>\n<p style=\"text-align: justify;\"><span style=\"color: #999999;\"><strong>Accuracy of Information<\/strong><\/span><br \/>\n<span style=\"color: #999999;\"> While we make reasonable efforts to give accurate and up-to-date information, we do not warrant that any information contained in or made available through this calculator is accurate, complete, reliable, current or error-free. We assume no liability or responsibility for any errors or omissions in the content of this GIN, grouting intensity number, online calculator or such.<\/span><br \/>\n<span style=\"color: #999999;\"> <strong> Disclaimer of Warranties and Limitations of Liability<\/strong><\/span><br \/>\n<span style=\"color: #999999;\"> This GIN, grouting intensity number, online calculator is provided on an \u201cas is\u201d and \u201cas available\u201d basis. Use of this website is at your own risk. We disclaim all warranties. We shall not be liable for any damages of any kind with the use of this GIN, grouting intensity number, online calculator.<\/span><\/p>\n<p>Please contact us to report errors or bugs.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This is a GIN, grouting intensity number, online calculator. It is useful to evaluate if a grout injection is within GIN specifications. To use this calculator: &#8211; set the length of the treatment (expressed in meters) and the grout pressure unit of measurement; &#8211; set maximum injection parameters (grout pressure, grout volume in liters per [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[33],"tags":[],"class_list":["post-3412","post","type-post","status-publish","format-standard","hentry","category-calculators"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.8.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>GIN, grouting intensity number, online calculator - DAT instruments<\/title>\n<meta name=\"description\" content=\"This is a GIN, grouting intensity number, online calculator. It is useful to evaluate if a grout injection is within GIN specifications\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"GIN, grouting intensity number, online calculator - DAT instruments\" \/>\n<meta property=\"og:description\" content=\"This is a GIN, grouting intensity number, online calculator. It is useful to evaluate if a grout injection is within GIN specifications\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/\" \/>\n<meta property=\"og:site_name\" content=\"DAT instruments\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/datinstruments\" \/>\n<meta property=\"article:published_time\" content=\"2018-03-25T19:56:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2018-03-26T09:03:12+00:00\" \/>\n<meta name=\"author\" content=\"datinstruments\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@DATinstruments\" \/>\n<meta name=\"twitter:site\" content=\"@DATinstruments\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"datinstruments\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/\"},\"author\":{\"name\":\"datinstruments\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/#\/schema\/person\/0deb912c4051bca42069c853ca0ee839\"},\"headline\":\"GIN, grouting intensity number, online calculator\",\"datePublished\":\"2018-03-25T19:56:14+00:00\",\"dateModified\":\"2018-03-26T09:03:12+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/\"},\"wordCount\":240,\"publisher\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/#organization\"},\"articleSection\":[\"Online calculators for Geotechnics\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/\",\"url\":\"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/\",\"name\":\"GIN, grouting intensity number, online calculator - DAT instruments\",\"isPartOf\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/#website\"},\"datePublished\":\"2018-03-25T19:56:14+00:00\",\"dateModified\":\"2018-03-26T09:03:12+00:00\",\"description\":\"This is a GIN, grouting intensity number, online calculator. It is useful to evaluate if a grout injection is within GIN specifications\",\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/\"]}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/#website\",\"url\":\"https:\/\/www.datinstruments.com\/en\/\",\"name\":\"DAT instruments\",\"description\":\"DAT instruments, datalogger for: Jet grouting - Grouting - Cement injection - TAM grouting - Drilling - MWD - CFA - Deep mixing - Soil mixing - Vibroflotation - Diaphragm walls - Hydromills - Lugeon test - Mineral investigation\",\"publisher\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.datinstruments.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/#organization\",\"name\":\"DAT instruments\",\"url\":\"https:\/\/www.datinstruments.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.datinstruments.com\/en\/files\/2019\/08\/User.jpg\",\"contentUrl\":\"https:\/\/www.datinstruments.com\/en\/files\/2019\/08\/User.jpg\",\"width\":567,\"height\":567,\"caption\":\"DAT instruments\"},\"image\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"http:\/\/www.facebook.com\/datinstruments\",\"https:\/\/x.com\/DATinstruments\",\"http:\/\/www.linkedin.com\/company\/dat-instruments\",\"http:\/\/www.youtube.com\/user\/DATinstruments\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/#\/schema\/person\/0deb912c4051bca42069c853ca0ee839\",\"name\":\"datinstruments\",\"sameAs\":[\"http:\/\/www.datinstruments.com\"],\"url\":\"https:\/\/www.datinstruments.com\/en\/author\/datinstruments\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"GIN, grouting intensity number, online calculator - DAT instruments","description":"This is a GIN, grouting intensity number, online calculator. It is useful to evaluate if a grout injection is within GIN specifications","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/","og_locale":"en_GB","og_type":"article","og_title":"GIN, grouting intensity number, online calculator - DAT instruments","og_description":"This is a GIN, grouting intensity number, online calculator. It is useful to evaluate if a grout injection is within GIN specifications","og_url":"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/","og_site_name":"DAT instruments","article_publisher":"http:\/\/www.facebook.com\/datinstruments","article_published_time":"2018-03-25T19:56:14+00:00","article_modified_time":"2018-03-26T09:03:12+00:00","author":"datinstruments","twitter_card":"summary_large_image","twitter_creator":"@DATinstruments","twitter_site":"@DATinstruments","twitter_misc":{"Written by":"datinstruments","Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/#article","isPartOf":{"@id":"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/"},"author":{"name":"datinstruments","@id":"https:\/\/www.datinstruments.com\/en\/#\/schema\/person\/0deb912c4051bca42069c853ca0ee839"},"headline":"GIN, grouting intensity number, online calculator","datePublished":"2018-03-25T19:56:14+00:00","dateModified":"2018-03-26T09:03:12+00:00","mainEntityOfPage":{"@id":"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/"},"wordCount":240,"publisher":{"@id":"https:\/\/www.datinstruments.com\/en\/#organization"},"articleSection":["Online calculators for Geotechnics"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/","url":"https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/","name":"GIN, grouting intensity number, online calculator - DAT instruments","isPartOf":{"@id":"https:\/\/www.datinstruments.com\/en\/#website"},"datePublished":"2018-03-25T19:56:14+00:00","dateModified":"2018-03-26T09:03:12+00:00","description":"This is a GIN, grouting intensity number, online calculator. It is useful to evaluate if a grout injection is within GIN specifications","inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.datinstruments.com\/en\/gin-grouting-intensity-number-online-calculator\/"]}]},{"@type":"WebSite","@id":"https:\/\/www.datinstruments.com\/en\/#website","url":"https:\/\/www.datinstruments.com\/en\/","name":"DAT instruments","description":"DAT instruments, datalogger for: Jet grouting - Grouting - Cement injection - TAM grouting - Drilling - MWD - CFA - Deep mixing - Soil mixing - Vibroflotation - Diaphragm walls - Hydromills - Lugeon test - Mineral investigation","publisher":{"@id":"https:\/\/www.datinstruments.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.datinstruments.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.datinstruments.com\/en\/#organization","name":"DAT instruments","url":"https:\/\/www.datinstruments.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.datinstruments.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.datinstruments.com\/en\/files\/2019\/08\/User.jpg","contentUrl":"https:\/\/www.datinstruments.com\/en\/files\/2019\/08\/User.jpg","width":567,"height":567,"caption":"DAT instruments"},"image":{"@id":"https:\/\/www.datinstruments.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/datinstruments","https:\/\/x.com\/DATinstruments","http:\/\/www.linkedin.com\/company\/dat-instruments","http:\/\/www.youtube.com\/user\/DATinstruments"]},{"@type":"Person","@id":"https:\/\/www.datinstruments.com\/en\/#\/schema\/person\/0deb912c4051bca42069c853ca0ee839","name":"datinstruments","sameAs":["http:\/\/www.datinstruments.com"],"url":"https:\/\/www.datinstruments.com\/en\/author\/datinstruments\/"}]}},"_links":{"self":[{"href":"https:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/posts\/3412","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/comments?post=3412"}],"version-history":[{"count":0,"href":"https:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/posts\/3412\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/media?parent=3412"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/categories?post=3412"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/tags?post=3412"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}