{"id":3407,"date":"2018-03-25T16:28:45","date_gmt":"2018-03-25T15:28:45","guid":{"rendered":"http:\/\/www.datinstruments.com\/en\/?p=3407"},"modified":"2018-03-26T10:03:32","modified_gmt":"2018-03-26T09:03:32","slug":"lugeon-test-online-calculator","status":"publish","type":"post","link":"http:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/","title":{"rendered":"Lugeon test, complete online calculator"},"content":{"rendered":"<p style=\"text-align: justify;\">This is an online Lugeon Test calculator. It is useful to calculate Lugeon Value in permeability tests, given water pressure (in bar, MegaPascal or PSI), water volume (in liters), test duration (in minutes) and length of borehole test interval (in meters). The output is the maximum or average Lugeon Value. The Lugeon Value is defined as the loss of water in liters per minute and per meter borehole at a pressure of 10 bar.<\/p>\n<p><style>@media (max-width:480px){#cp_calculatedfieldsf_pform_1{min-height:2416px;}}@media (max-width:768px){#cp_calculatedfieldsf_pform_1{min-height:2290px;}}@media (max-width:1024px){#cp_calculatedfieldsf_pform_1{min-height:2293px;}}@media (min-width:1024px){#cp_calculatedfieldsf_pform_1{min-height:2437px;}}<\/style><form name=\"cp_calculatedfieldsf_pform_1\" id=\"cp_calculatedfieldsf_pform_1\" action=\"http:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/\" method=\"post\" enctype=\"multipart\/form-data\" onsubmit=\"return fbuilderjQuery.fbuilder.doValidate(this);\" class=\"cff-form \"  dir=\"ltr\" data-nonce=\"e25e709e50\">\n<input type=\"hidden\" name=\"cp_calculatedfieldsf_pform_psequence\" value=\"_1\" \/>\n<input type=\"hidden\" name=\"cp_calculatedfieldsf_id\" value=\"7\" \/>\n<input type=\"hidden\" name=\"cp_ref_page\" value=\"http:\/\/www.datinstruments.com\/en\" \/>\n<pre style=\"display:none !important;\"><script type=\"text\/javascript\">form_structure_1=[[{\"form_identifier\":\"\",\"name\":\"fieldname15\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":0,\"ftype\":\"fSectionBreak\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon test set up\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname14\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":1,\"ftype\":\"fradio\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Set pressure unit of measurement\",\"layout\":\"side_by_side\",\"required\":false,\"exclude\":false,\"readonly\":false,\"toSubmit\":\"value\",\"choiceSelected\":\"BAR - 1\",\"showDep\":false,\"untickAccepted\":true,\"onoff\":0,\"choices\":[\"BAR\",\"MPa\",\"PSI\"],\"choicesVal\":[\"1\",\"10\",\"0.06894757\"],\"choicesDep\":[[],[],[]],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname20\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":2,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Set pressure gauge height [m]\",\"predefined\":\"0.5\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname24\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":3,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Set length of the borehole test interval [m]\",\"predefined\":\"1\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname21\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":4,\"ftype\":\"fSectionBreak\",\"userhelp\":\"All following parameters refer to the step 1\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon test, step 1\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname2\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":5,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Pressure value\",\"predefined\":\"5\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname18\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":6,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Pumped water volume [l]\",\"predefined\":\"100\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname19\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":7,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Duration [min]\",\"predefined\":\"10\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname22\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":8,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Flow rate [l\\\/min]\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec(fieldname18 \\\/ fieldname19, 1)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":false,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname25\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":9,\"ftype\":\"fSectionBreak\",\"userhelp\":\"All following parameters refer to the step 2\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon test, step 2\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname26\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":10,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Pressure value\",\"predefined\":\"7.5\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname27\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":11,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Pumped water volume [l]\",\"predefined\":\"200\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname28\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":12,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Duration [min]\",\"predefined\":\"10\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname29\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":13,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Flow rate [l\\\/min]\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec(fieldname27 \\\/ fieldname28, 1)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":false,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname31\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":14,\"ftype\":\"fSectionBreak\",\"userhelp\":\"All following parameters refer to the step 3\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon test, step 3\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname32\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":15,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Pressure value\",\"predefined\":\"10\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname33\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":16,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Pumped water volume [l]\",\"predefined\":\"300\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname34\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":17,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Duration [min]\",\"predefined\":\"10\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname35\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":18,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Flow rate [l\\\/min]\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec(fieldname33 \\\/ fieldname34, 1)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":false,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname37\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":19,\"ftype\":\"fSectionBreak\",\"userhelp\":\"All following parameters refer to the step 4\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon test, step 4\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname38\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":20,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Pressure value\",\"predefined\":\"7.5\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname39\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":21,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Pumped water volume [l]\",\"predefined\":\"200\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname40\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":22,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Duration [min]\",\"predefined\":\"10\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname41\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":23,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Flow rate [l\\\/min]\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec(fieldname39 \\\/ fieldname40, 1)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":false,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname43\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":24,\"ftype\":\"fSectionBreak\",\"userhelp\":\"All following parameters refer to the step 5\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon test, step 5\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname44\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":25,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Pressure value\",\"predefined\":\"5\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname45\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":26,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Pumped water volume [l]\",\"predefined\":\"100\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname46\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":27,\"ftype\":\"fnumber\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Duration [min]\",\"predefined\":\"10\",\"predefinedClick\":false,\"required\":false,\"exclude\":false,\"readonly\":false,\"numberpad\":false,\"spinner\":false,\"size\":\"medium\",\"prefix\":\"\",\"postfix\":\"\",\"thousandSeparator\":\"\",\"decimalSymbol\":\".\",\"min\":\"\",\"max\":\"\",\"step\":\"\",\"formatDynamically\":false,\"dformat\":\"number\",\"formats\":[\"digits\",\"number\",\"percent\"],\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname47\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":28,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Flow rate [l\\\/min]\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec(fieldname45 \\\/ fieldname46, 1)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":false,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"},{\"form_identifier\":\"\",\"name\":\"fieldname12\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":29,\"ftype\":\"fSectionBreak\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon test results\",\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname23\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":30,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon value, step 1\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec(fieldname22 \\\/ fieldname24 * 10 \\\/ (fieldname2 * fieldname14 + fieldname20 * 0.0981), 2)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":true,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname30\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":31,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon value, step 2\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec(fieldname29 \\\/ fieldname24 * 10 \\\/ (fieldname26 * fieldname14 + fieldname20 * 0.0981), 2)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":true,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname36\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":32,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon value, step 3\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec(fieldname35 \\\/ fieldname24 * 10 \\\/ (fieldname32 * fieldname14 + fieldname20 * 0.0981), 2)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":true,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname42\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":33,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon value, step 4\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec(fieldname41 \\\/ fieldname24 * 10 \\\/ (fieldname38 * fieldname14 + fieldname20 * 0.0981), 2)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":true,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname48\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":34,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon value, step 5\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec(fieldname47 \\\/ fieldname24 * 10 \\\/ (fieldname44 * fieldname14 + fieldname20 * 0.0981), 2)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":true,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname49\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":35,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon value, maximum\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec(max(fieldname23, fieldname30, fieldname36, fieldname42, fieldname48), 2)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":false,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"},{\"dependencies\":[{\"rule\":\"\",\"complex\":false,\"fields\":[\"\"]}],\"form_identifier\":\"\",\"name\":\"fieldname50\",\"fieldlayout\":\"default\",\"shortlabel\":\"\",\"index\":36,\"ftype\":\"fCalculated\",\"userhelp\":\"\",\"audiotutorial\":\"\",\"userhelpTooltip\":false,\"tooltipIcon\":false,\"csslayout\":\"\",\"title\":\"Lugeon value, average\",\"predefined\":\"\",\"required\":false,\"exclude\":false,\"size\":\"medium\",\"eq\":\"prec((fieldname23 + fieldname30 + fieldname36 + fieldname42 + fieldname48) \\\/ 5, 2)\",\"min\":\"\",\"max\":\"\",\"suffix\":\"\",\"prefix\":\"\",\"decimalsymbol\":\".\",\"groupingsymbol\":\"\",\"readonly\":true,\"currency\":false,\"noEvalIfManual\":true,\"formatDynamically\":false,\"dynamicEval\":true,\"hidefield\":false,\"validate\":false,\"toolbar\":\"default|mathematical\",\"fBuild\":{},\"parent\":\"\"}],{\"0\":{\"title\":\"\",\"description\":\"\",\"formlayout\":\"top_aligned\",\"formtemplate\":\"\",\"evalequations\":1,\"autocomplete\":1,\"persistence\":0,\"customstyles\":\"\",\"titletag\":\"H2\",\"textalign\":\"default\",\"headertextcolor\":\"\",\"evalequations_delay\":0,\"evalequationsevent\":2,\"direction\":\"ltr\",\"loading_animation\":0,\"animate_form\":0,\"animation_effect\":\"fade\"},\"formid\":\"cp_calculatedfieldsf_pform_1\"}];<\/script><\/pre>\n<div id=\"fbuilder\">\n\t\t<div id=\"fbuilder_1\">\n\t\t<div id=\"formheader_1\"><\/div>\n\t\t<div id=\"fieldlist_1\"><\/div>\n\t\t<div class=\"clearer\"><\/div>\n\t<\/div>\n<\/div>\n\t<div class=\"clearer\"><\/div>\n\t<input type=\"hidden\" id=\"_cpcff_public_nonce\" name=\"_cpcff_public_nonce\" value=\"256df6f232\" \/><input type=\"hidden\" name=\"_wp_http_referer\" value=\"\/en\/wp-json\/wp\/v2\/posts\/3407\" \/><\/form>\n\t<br \/>\n<a href=\"http:\/\/www.datinstruments.com\/en\/lugeon-tests\/\">Automatic Lugeon Tests recorder<\/a><\/p>\n<p>Reference: Maurice Lugeon, Dams and Geology (1933)<\/p>\n<p style=\"text-align: justify;\">The following table describes the conditions typically associated with different Lugeon values (Qui\u00f1ones-Rozo, 2010):<\/p>\n<table border=\"0\" width=\"100%\" cellspacing=\"0\" cellpadding=\"3\">\n<tbody>\n<tr>\n<td width=\"92\">Lugeon Value<\/td>\n<td width=\"161\">Classification<\/td>\n<td width=\"228\">Rock discontinuity condition<\/td>\n<\/tr>\n<tr>\n<td>\u00a0&lt;1<\/td>\n<td>\u00a0Very low<\/td>\n<td>\u00a0Very tight<\/td>\n<\/tr>\n<tr>\n<td>\u00a01-5<\/td>\n<td>\u00a0Low<\/td>\n<td>\u00a0Tight<\/td>\n<\/tr>\n<tr>\n<td>\u00a05-15<\/td>\n<td>\u00a0Moderate<\/td>\n<td>\u00a0Few partly open<\/td>\n<\/tr>\n<tr>\n<td>\u00a015-50<\/td>\n<td>\u00a0Medium<\/td>\n<td>\u00a0Some open<\/td>\n<\/tr>\n<tr>\n<td>\u00a050-100<\/td>\n<td>\u00a0High<\/td>\n<td>\u00a0Many open<\/td>\n<\/tr>\n<tr>\n<td>\u00a0&gt;100<\/td>\n<td>\u00a0Very high<\/td>\n<td>\u00a0Open closely spaced or voids<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<hr \/>\n<p style=\"text-align: justify;\"><span style=\"color: #999999;\"><strong>Accuracy of Information<\/strong><\/span><br \/>\n<span style=\"color: #999999;\"> While we make reasonable efforts to give accurate and up-to-date information, we do not warrant that any information contained in or made available through this calculator is accurate, complete, reliable, current or error-free. We assume no liability or responsibility for any errors or omissions in the content of this Lugeon Test calculator or such.<\/span><br \/>\n<span style=\"color: #999999;\"> <strong> Disclaimer of Warranties and Limitations of Liability<\/strong><\/span><br \/>\n<span style=\"color: #999999;\"> This Lugeon Test calculator is provided on an \u201cas is\u201d and \u201cas available\u201d basis. Use of this website is at your own risk. We disclaim all warranties. We shall not be liable for any damages of any kind with the use of this Lugeon Test calculator.<\/span><\/p>\n<p>Please contact us to report errors or bugs.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This is an online Lugeon Test calculator. It is useful to calculate Lugeon Value in permeability tests, given water pressure (in bar, MegaPascal or PSI), water volume (in liters), test duration (in minutes) and length of borehole test interval (in meters). The output is the maximum or average Lugeon Value. The Lugeon Value is defined [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[33],"tags":[],"class_list":["post-3407","post","type-post","status-publish","format-standard","hentry","category-calculators"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.8.1 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Lugeon test, complete online calculator - DAT instruments<\/title>\n<meta name=\"description\" content=\"This is an online Lugeon Test calculator. It is useful to calculate Lugeon Value in permeability tests, given water pressure (in bar, MegaPascal or PSI), water volume (in liters) and test duration (in minutes). The output is the maximum or average Lugeon Value.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lugeon test, complete online calculator - DAT instruments\" \/>\n<meta property=\"og:description\" content=\"This is an online Lugeon Test calculator. It is useful to calculate Lugeon Value in permeability tests, given water pressure (in bar, MegaPascal or PSI), water volume (in liters) and test duration (in minutes). The output is the maximum or average Lugeon Value.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/\" \/>\n<meta property=\"og:site_name\" content=\"DAT instruments\" \/>\n<meta property=\"article:publisher\" content=\"http:\/\/www.facebook.com\/datinstruments\" \/>\n<meta property=\"article:published_time\" content=\"2018-03-25T15:28:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2018-03-26T09:03:32+00:00\" \/>\n<meta name=\"author\" content=\"datinstruments\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@DATinstruments\" \/>\n<meta name=\"twitter:site\" content=\"@DATinstruments\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"datinstruments\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/\"},\"author\":{\"name\":\"datinstruments\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/#\/schema\/person\/0deb912c4051bca42069c853ca0ee839\"},\"headline\":\"Lugeon test, complete online calculator\",\"datePublished\":\"2018-03-25T15:28:45+00:00\",\"dateModified\":\"2018-03-26T09:03:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/\"},\"wordCount\":260,\"publisher\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/#organization\"},\"articleSection\":[\"Online calculators for Geotechnics\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/\",\"url\":\"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/\",\"name\":\"Lugeon test, complete online calculator - DAT instruments\",\"isPartOf\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/#website\"},\"datePublished\":\"2018-03-25T15:28:45+00:00\",\"dateModified\":\"2018-03-26T09:03:32+00:00\",\"description\":\"This is an online Lugeon Test calculator. It is useful to calculate Lugeon Value in permeability tests, given water pressure (in bar, MegaPascal or PSI), water volume (in liters) and test duration (in minutes). The output is the maximum or average Lugeon Value.\",\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/\"]}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/#website\",\"url\":\"https:\/\/www.datinstruments.com\/en\/\",\"name\":\"DAT instruments\",\"description\":\"DAT instruments, datalogger for: Jet grouting - Grouting - Cement injection - TAM grouting - Drilling - MWD - CFA - Deep mixing - Soil mixing - Vibroflotation - Diaphragm walls - Hydromills - Lugeon test - Mineral investigation\",\"publisher\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.datinstruments.com\/en\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/#organization\",\"name\":\"DAT instruments\",\"url\":\"https:\/\/www.datinstruments.com\/en\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.datinstruments.com\/en\/files\/2019\/08\/User.jpg\",\"contentUrl\":\"https:\/\/www.datinstruments.com\/en\/files\/2019\/08\/User.jpg\",\"width\":567,\"height\":567,\"caption\":\"DAT instruments\"},\"image\":{\"@id\":\"https:\/\/www.datinstruments.com\/en\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"http:\/\/www.facebook.com\/datinstruments\",\"https:\/\/x.com\/DATinstruments\",\"http:\/\/www.linkedin.com\/company\/dat-instruments\",\"http:\/\/www.youtube.com\/user\/DATinstruments\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.datinstruments.com\/en\/#\/schema\/person\/0deb912c4051bca42069c853ca0ee839\",\"name\":\"datinstruments\",\"sameAs\":[\"http:\/\/www.datinstruments.com\"],\"url\":\"http:\/\/www.datinstruments.com\/en\/author\/datinstruments\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Lugeon test, complete online calculator - DAT instruments","description":"This is an online Lugeon Test calculator. It is useful to calculate Lugeon Value in permeability tests, given water pressure (in bar, MegaPascal or PSI), water volume (in liters) and test duration (in minutes). The output is the maximum or average Lugeon Value.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/","og_locale":"en_GB","og_type":"article","og_title":"Lugeon test, complete online calculator - DAT instruments","og_description":"This is an online Lugeon Test calculator. It is useful to calculate Lugeon Value in permeability tests, given water pressure (in bar, MegaPascal or PSI), water volume (in liters) and test duration (in minutes). The output is the maximum or average Lugeon Value.","og_url":"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/","og_site_name":"DAT instruments","article_publisher":"http:\/\/www.facebook.com\/datinstruments","article_published_time":"2018-03-25T15:28:45+00:00","article_modified_time":"2018-03-26T09:03:32+00:00","author":"datinstruments","twitter_card":"summary_large_image","twitter_creator":"@DATinstruments","twitter_site":"@DATinstruments","twitter_misc":{"Written by":"datinstruments","Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/#article","isPartOf":{"@id":"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/"},"author":{"name":"datinstruments","@id":"https:\/\/www.datinstruments.com\/en\/#\/schema\/person\/0deb912c4051bca42069c853ca0ee839"},"headline":"Lugeon test, complete online calculator","datePublished":"2018-03-25T15:28:45+00:00","dateModified":"2018-03-26T09:03:32+00:00","mainEntityOfPage":{"@id":"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/"},"wordCount":260,"publisher":{"@id":"https:\/\/www.datinstruments.com\/en\/#organization"},"articleSection":["Online calculators for Geotechnics"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/","url":"https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/","name":"Lugeon test, complete online calculator - DAT instruments","isPartOf":{"@id":"https:\/\/www.datinstruments.com\/en\/#website"},"datePublished":"2018-03-25T15:28:45+00:00","dateModified":"2018-03-26T09:03:32+00:00","description":"This is an online Lugeon Test calculator. It is useful to calculate Lugeon Value in permeability tests, given water pressure (in bar, MegaPascal or PSI), water volume (in liters) and test duration (in minutes). The output is the maximum or average Lugeon Value.","inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.datinstruments.com\/en\/lugeon-test-online-calculator\/"]}]},{"@type":"WebSite","@id":"https:\/\/www.datinstruments.com\/en\/#website","url":"https:\/\/www.datinstruments.com\/en\/","name":"DAT instruments","description":"DAT instruments, datalogger for: Jet grouting - Grouting - Cement injection - TAM grouting - Drilling - MWD - CFA - Deep mixing - Soil mixing - Vibroflotation - Diaphragm walls - Hydromills - Lugeon test - Mineral investigation","publisher":{"@id":"https:\/\/www.datinstruments.com\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.datinstruments.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.datinstruments.com\/en\/#organization","name":"DAT instruments","url":"https:\/\/www.datinstruments.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.datinstruments.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/www.datinstruments.com\/en\/files\/2019\/08\/User.jpg","contentUrl":"https:\/\/www.datinstruments.com\/en\/files\/2019\/08\/User.jpg","width":567,"height":567,"caption":"DAT instruments"},"image":{"@id":"https:\/\/www.datinstruments.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["http:\/\/www.facebook.com\/datinstruments","https:\/\/x.com\/DATinstruments","http:\/\/www.linkedin.com\/company\/dat-instruments","http:\/\/www.youtube.com\/user\/DATinstruments"]},{"@type":"Person","@id":"https:\/\/www.datinstruments.com\/en\/#\/schema\/person\/0deb912c4051bca42069c853ca0ee839","name":"datinstruments","sameAs":["http:\/\/www.datinstruments.com"],"url":"http:\/\/www.datinstruments.com\/en\/author\/datinstruments\/"}]}},"_links":{"self":[{"href":"http:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/posts\/3407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/comments?post=3407"}],"version-history":[{"count":0,"href":"http:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/posts\/3407\/revisions"}],"wp:attachment":[{"href":"http:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/media?parent=3407"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/categories?post=3407"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.datinstruments.com\/en\/wp-json\/wp\/v2\/tags?post=3407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}